Description
Product Description
The new model, 6 parameters of the 7 wave, 10.4 ” color TFT-LCD display screen. Selection of NELLCOR oxygen plate or a digital oxygen plate. Resistance to weak pulse, anti motion interference, brightness adjustable volume unique. High-energy rechargeable battery.
1.Super ability in against electrosurgical interference. Neither in cutting nor in burning, ECG waveform and HR can be influenced, very short recovering time after defibrillation, especially suitable for use in emergency or operating room.
2.Unique thoracic impedance & nasal tube double model respiration test method (when patient can not lie quietly, only nasal tube respiration can detect the right respiration waveform and respiration rate).
3.10.4 color TFT LCD screen, High brightness,Wide viewing, 7 waveforms can be displayed on the same screen . lightness and volume are adjustable independently.
4.Streamlined outline design with sense of the times & foldable handle.
5. Multi-language interface selection: Chinese, English, Spanish, Portuguese, French, Arabic, Russian, Italian, Turkish, etc.
ECG
Heart rate(HR)
Measurement range: 30BPM ~ 300BPM;
Accuracy: 1 BPM or ±1 %.
Heart rate alarm settings And tolerance: upper limit (60 ~ 300) bpm; tolerance::± 10% Lower limit (10 ~ 200) bpm; tolerance : ± 10%
Noise level: ≤ 30μV
ECG frequency response: filtering methods: (1 ~ 25) HzNon-filtered mode: (0.05 ~ 100) Hz The ECG Input circuit current: ≤ 0.1μAECG sensitivity: continuous adjustable
The scanning speed of the sub-file and error:Scan rate can be divided into three files for selection: 12.5mm / s, 25mm / s, 50mm / sThe error of scanning rate: ≤ ± 10%
NIBP
Measurement range:
Systolic(SBP):(5.3 ~ 36.0)kPa,or(40 ~ 270 )mmHg
Diastolic (DBP):(2.7 ~ 26.7)kPa,or(20 ~ 200 )mmHg
Mean (MAP):(4.0 ~ 29.3)kPa,or(30 ~ 220 )mmHg
Accuracy : ≤ ± 0.4 kPa (3 mmHg) or ±2%,
IBP
Measurement range: -1.3~40KPa(-10 ~ 300mmHg)
Channel: 2 channelsTransducer sensitivity: 5MV/V/mmHg
Unit display: kPa or mmHg( selectable)
Respiration Rate
Measurement range: 0 BPM ~ 120 BPM;
Accuracy: ±1 BPM or ±5 %
Temperature
Number of channels: 2
Temperature probe configuration: Intracavitary probe: 1 unit; Surface probe: 1 unit
Measurement range: 25.0 ℃~ 45.0℃
Accuracy: ± 0.2 ℃
Response time: ≤ 3 min.
SpO2
Display type: Waveform, data
Measurement range: 0~100%
Resolution: 1 BPM
Pulse rate range: 30~250bpm
Accuracy: ±1bpm
Pulse Rate
Measurement range: (30 ~ 250)bpm;
Accuracy: 1BPM or ±2%
Trend review:
Can Review history data of 360 hours
CO2:
Measurement range: 0﹪ ~ 10.0﹪ ( Carbon dioxide inhalation and carbon dioxide exhalation)
Accuracy: ±2mmHg(<5﹪ Measured values)
10﹪(>5﹪ Measured values)








Genius™ Digital Imager
Mindray Vet DP-2200 Veterinary Equine Repro Ultrasound
Elisa washer, MPW-H310, MPW-H320
ThinPrep® 5000 Processor
ThinPrep® Processors
Genius™ Digital Diagnostics System
Mindray BC-3000Plus Auto Hematology Analyzer
Tomcat®
Hycel HYCHEM 400 Automatic Biochemistry Analyzer
EXZ 6000 Hematology Analyzer
Tablet Hardness Tester, THT-II
Tablet Hardness Tester
Sfri HEMIX 5-60 Hematology Analyzer
Sfri ISE SERIES PH Electrolyte Analyzer
Mindray DC6 Diagnostic Ultrasound System
Sfri H18 LIGHT Hematology Analyzer
Elisa Reader, automatic, MPR-D110
HORIBA Pentra DF Nexus SPS Evolution Hematology Analyzer
Elisa Reader, MPR-A200HT,MPR-A200
Abbott Cell-Dyn 3500 SL Hematology Analyzers
Portable Veterinary Digital X-Ray (DR) for Equine YR06161
Abbott Cell-Dyn 4000 Hematology Analyzer
Reviews
There are no reviews yet.