Description
The APSA-380 is an analyzer for measuring sulfur dioxide in ambient air and other background gases, for air quality control as well as for variety of industrial applications. HORIBA’s state-of-the-art ultraviolet fluorescence (UVF) technology enables high sensitivity and stable real-time continuous measurement.
Ultimate Performance
Ultraviolet fluorescence technology provides excellent sensitivity, stability and robustness
Real-time continuous measurement
Wide measurement range with up to 8 ranges selectable, minimum 0-0.05 ppm and maximum 0-20 ppm
UV fluorescence detector and integrated HC cutter eliminate interference from moisture and coexisting components
Incorporated UV lamp intensity compensator
Enhanced Lower Detection Limit and response time
User-Friendly Interface & Functionality
Durable 7-inch wide color touch screen LCD with intuitive interface and trend graph
Selectable metrics (ppb, μg/m3, ppm, mg/m3), response time (moving average value), and calculation method
Programmable dilution ratio
Dust filter accessible from the front panel for easy daily maintenance
â– APSA-380 Specifications
Component Sulfur dioxide (SO2)
Measuring principle Ultraviolet Fluorescence
Measurement range 0-0.05/0.1/0.2/0.5/1.0/5.0/10/20 ppm (up to 8 ranges selectable, auto-range)*1
Lower Detection Limit (2σ) < 0.3 ppb*2*3
Measurement unit ppb, µg/m3, ppm, mg/m3
Sample gas flow rate Approx. 0.6 L/min
Repeatability ±1.0% of full scale
Linearity ±1.0% of full scale
Zero drift < 0.5 ppb (24 h)
Span drift < 0.5% of full scale (24 h)
Response time (T95) < 120 s from the inlet*3
Display 7-inch color LCD with touch panel
Communication Ethernet × 2 (Modbus® TCP), RS-232C × 1 (Modbus® RTU) , USB flash drive × 1
Analog output (option) Maximum : 3 channels (insulated)
DC4-20 mA, DC 0-0.1 V, DC 0-1 V, DC 0-5 V or DC 0-10 V
Digital output (option) Relay contact output for range 3 channels, relay contact output for other 6 channels
Digital input (option) Maximum : 4 channels, non-isolated input
Installation environment Operation temperature : 0-40℃ (32℉ – 104℉), relative humidity : 85% or less
Temperature and pressure compensation With
Sampling pump and filter Internal
Power supply AC 100-240V ±10% (max. voltage: AC 250 V), 50/60 Hz, consumption 50 W
Dimensions, weight 430 (W) x 568 (D) x 221 (H) mm, Approx. 18 kg
Compliance CE, UKCA, KC, FCC, China RoHS








HORIBA Pentra DF Nexus Hematology Analyzer
HORIBA Pentra ES 60 Hematology Analyzer
HORIBA Pentra DX Nexus Hematology Analyzer
HORIBA ABX ABX Pentra DF 120 SPS Hematology Analyzer
HORIBA ABX Pentra DF 120 Hematology Analyzer
HORIBA Yumizen H500 OT Hematology Analyzer
Horiba Yumizen P8000 Hematology Analyzers
Horiba Yumizen G800 Automated Coagulation Analyzer
Horiba Yumizen G200 Semi Automated Coagulation Analyzer
Horiba Yumizen G100 Yumizen G100 Whole Blood Point of Care System
Portable Conductivity/DO Meter YR06382
Electrolyte Analyzer YR06407// YR06417
Household Type Ultrasonic Cleaner YR05230
120KG Tumble Dryer (With Coated) GAS YR06333
Washer/Dryer Gas Heating (Full Stainless Steel) YR06341
Aqualog - A-TEEM Industrial QC/QA Analyzer
Beckman Coulter DxH 900 Workcell Automated Hematology Solution
CEM500 Online Gas Analyser
Beckman Coulter DxH 500 Hematology Analyzer
EXM500 Online Gas Analyser
Cassette Autoclave, STC-6000
AP-370 Series Air Pollution Monitor
Reviews
There are no reviews yet.