Description
Description
Atomic Absorption Spectrophotometer
Features
1. Build-in computer data processing and LCD display: stable and reliable with the functions of integral holding, peak height and area, auto zero adjusting, deuterium lamp background correction, multi-linear and nonlinear curves fitting, various parameters and working curves displayed in screen and report printing, etc. It is equipped with interface for externally linking PC.
2. Stability: Double-beam system can automatically compensate the light source drift and wavelength drift caused by the variation of temperature (with the function of the eliminating the affection of wavelength drift on the base line stability) and electronic circuit drift so as to reach a good basic line stability.
3. Quickly: The cathode lamp needs not be pre-heated for long time and sample can be analyzed immediately. It is the preferable instrument chosen by users to conduct analysis of multiple kinds of elements and fast analysis of samples.
4. High precision of measurement: Gas path system is equipped with precision pressure stabilizing and current stabiliz- ing devices to reach stable flame and low noise. Specially designed fine light beam passes through the flame to ensure a high precision analytical test and low characteristic concentration
5. High energy optical path: A total reflection system is adopted to eliminate color difference in full range. By means of chemical conversion, a round light spot of the light source becomes a long light spot, which enters into the slit. There-
fore the light flux of double beam is enhanced.
6. Long-life and anti-corrosive atomization system: The burner is made of new type titanium alloys, anti-corrosive and fast thermal equilibrium. It meets the requirement of measurement sensitivity without water-cooling.
7. Multi-functional analysis mode: for methods of flame absorption, flame emission, graphite furnace atomic absorption and hydride generation.
8. Safe and reliable gas path system: Special devices of quick gas conversion and safety protectioncan be used to analyze air-acetylene flame.
9. Complete set of accessories: to be supplied with the instrument and ready for use after they are purchased.
Model SP-IAA320
WL Range 190 – 900nm
WL accuracy ≤±0.5nm
WL repeatability ≤0.3nm (single direction)
Spectrum bandwidth 0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nm, 5.0nm
Resolution ≤40%
Base line stability ±0.004Abs/30min
Characteristic concentration of cooper ≤ 0.04μg/ml/1%
Detection limit of copper ≤0.08μg/ml
Background calibration ability Greater than 30 times
RS232 including
Printer optional
Electricity 220V 3A 50HZ
Power 200W
G.W. 138KG 56KG
Package Dimensions 1250mmx795mmx765mm (Main instrument)
545mmx445mmx1385mm ( Accessories )
Standard Accessories
Oil-free air compressor
Glass Atomizer
Cu Hollow cathode lamp
Atomizer unit
Burner unit
Dust cover
Water-separating gas filter
Titanium burner—10cm
Optional Accessories
Model GRD-3202 graphite furnace system
Hydride generator
Hollow cathode lamp
Graphite tubes
Software
Recirculating cooling water system







Refrigerated Centrifuge, Low Speed, CFGR-5BL
Low-speed Refrigerated Centrifuge YR122
Handheld Veterinary Pulse Oximeter YR06107
Abbott Cell Dyn 3700 SL Hematology Analyzers
Low Speed Centrifuge, CFG-550JP
Fluoroscan® InSight® Mini C-arm Extremities Imaging System
Mini Centrifuge, High Speed, CFG-Mini15D
Digital Electrocardiograph COR-T12
TE Air i3P
Veterinary Digital X-Ray (DR) YR06162
Diatron Abacus Junior 30 Differential Hematology Analyzers
Hydrogen Peroxide Plasma Sterilizer, STV Series
Reviews