Description
Description
The Pulsating Vacuum Autoclave with Automatic Lifting Door YR05793 is a cutting-edge innovation in sterilization technology, designed to provide an efficient and safe process using saturated steam. This autoclave is equipped with a 7-inch color LCD touchscreen, allowing for fully automated and easy operation. Its automatic lifting door facilitates the loading and unloading of objects, enhancing user convenience and efficiency. The system dynamically displays critical parameters such as temperature, pressure, time, vacuum rate, drying, water level, and the entire cycle. From water intake to vacuum drying, the process is performed automatically with a single button press, ensuring that the residual moisture of instruments is less than 0.2%. Its versatility is evident with seven sterilization cycles tailored for instruments, textiles, rubber, liquids, and more, including specialized tests such as BOWIE & DICK and vacuum leak tests.
Safety Protection Device
Heater protection
Anti-dry heating
Safety interlock door: The program can’t start up when the door is unlocked under normal condition. Door is locked and the door can’t open when pressure in chamber.
Over-temperature protection: Adapt PT100 with accuracy class A for temperature control in chamber, collect temperature data in real-time, protect and alarm when temperature higher than default value.
Over-pressure protection: The relief valve starts to release pressure automatically when the pressure in chamber and steam generator exceed the default value.
Automatic release safety valve.
Over current protect.
Electric safety protective device: Fuse protects control units when short circuit or overload occurs.
Overheating protection device: High temperature deviation in chamber actuates protective device cuts off the heating source immediately.
Vacuum pump overload: The vacuum pump stops and alarms once its motor is overload or blocked when vacuum pump running.
Technical Specifications
Model YR05793
Max. Working pressure 0.23Mpa
Working pressure 0.22Mpa
Working temperature range 105 – 134℃
Vacuum rate -0.081Mpa
Accuracy of temperature display 0.1℃
Sterilization time 0 – 99 min
Drying time 0 – 99 min
Heat average ≤±1℃
Type Vertical Pulsating Vacuum Autoclave
Class Class B
Control Microprocessor
Door Automatic lifting door
Display LCD color touch screen display
Drying system Vacuum drying
Steam generator Separate steam generator
Vacuum pump Yes
Sterilization program Liquid, Instrument, Textile, Rubber, User-defined, Vacuum leakage test, B & D test
Water tank Yes
Printer Yes
Sterilization box 2 PCS
Language English
Voltage 220V, 50Hz, single-phase
Chamber Size (mm) Ø340×490 mm – 40L
Packing Size (mm) 786×656×1013
G.W. / N.W. 140 Kg
Power 5.4 KW+A12:B27








VARIANT II Hemoglobin Testing System
X-5000* Energy Dispersive X-ray Fluorescence Analyzer
Reviews
There are no reviews yet.