Description
Features
High Throughput
JCA-BM8000 series offers 1,200 TPH per module with connectivity of maximum 6 modules.
Minimizing the loss in throughput, dilution cuvettes are automatically transferred to the fastest, available module for assigned measurements.
Micro Volume Sampling Technology
JEOL’s outstanding sampling technology realizes micro volume sampling (minimum 2ÎĽL for primary samples and 1ÎĽL for diluted samples) for JCA-BM8000 series.
Auto Rerun
With its unique auto rerun mechanism, JCA-BM8000 series requires no re-loading of primary sample for auto rerun.
Back-up Capability
JCA-BM8000 series also offers “Backup” capability, depending on the test combination on the modules.
Ultra High Throughput (Analyzer Module)
The throughput of analyzer module of BM8000 series is maximum 1200 test per hour.
Each module is a random access single module so that it always maintains the highest possible throughput when integrated.
Maximum 50 reagents can be set on each module.
Specifications Note
Analyzer Module 1,200 test/H Reagent Pickup Type,
Random Access
Single Module
Minimum Sample
Volume 1.0 ÎĽL
Minimum Reaction
Volume 50 ÎĽL
On-board Reagent
availability Max. 50
bottles Available Large Bottles:
20ml, 40ml, 70ml:
Module Integration Up to 6
module Max. 7200 test/H
Sample Dilution Module (DEM) – ISE Units and CTT
The ISE units on the JCA-BM8000 series are 600 test/H/unit.
Maximum 3 units can be installed on the DEM.
BM8000 series also have Refrigerated Sample Tray (CTT).
Specifications
JCA-BM8020 JCA-BM8040 JCA-BM8060
Throughput Max. 4200 test/H
Photometry :Up to 2400 test/H
ISE:Up to 1800 test/H Max. 6600 test/H
Photometry :Up to 4800 test/H
ISE:Up to 1800 test/H Max. 9000 test/H
Photometry :Up to 7200 test/H
ISE: Up to 1800 test/H
Available Assays(including ISE) 203assays
Reaction Volume 50 to 120ÎĽL
Clot Detector Standard feature
Auto Hemolysis for HbA1C Not Available
Rack Handler Available
TLA connection Available
Sample Loading Rack Handler=Option:300 Samples
Sample tray:60 samples
Reaction time 3, 4, 5, 10 minutes
Reaction Bath Inert Oil (37°C±0.1°C)
Regent Bottle(ml) 20, 40, 70
Mixer Spin mixer
Water Usage(MAX) 59L / hour 104L / hour 149L / hour
Measurement points Maximum 64 points (10minute reaction time)
Measurement wavelengths 340 to 884 nm(14 wavelengths), 1 or 2 wavelengths for calculation
Size(mm) 3155(W)Ă—1350(D)Ă—1266(H) 4545(W)Ă—1350(D)Ă—1266(H) 5925(W)Ă—1350(D)Ă—1266(H)
Weight(Kg) 1260 1960 2660
Rack Handler (Optional)
Model name RH300
The maximum number of samples loaded 300 (5 positions times 30 racks times 2 lanes)
Sample containers 5mL, 7mL, and 10mL tubes
Rack ID Barcode controlled
Supply method Two supply lanes of front loading
STAT rack port on side
Racks Dedicated two lanes each with a tray as well as rack supply
Size Dimension: 1,105 (W) Ă— 1,315 (D) Ă— 1,266 (H) mm, Weight: 175 kg