Description
The MAB breakthrough analyzer is designed to analyze adsorption breakthrough curves for multi-component gas across a wide range of experimental conditions, including varying adsorbents, temperatures, pressures, bed thicknesses, gas concentrations, and flow rates. Equipped with a built-in thermal conductivity detector or out connected Mass Spectrometer, the BSD-MAB delivers highly accurate, real-time data on adsorption dynamics and breakthrough behaviors for a diverse array of gases and pollutants. This makes it an essential tool for both research and industrial applications. The BSD-MAB delivers critical insights into adsorption capacity, purification efficiency, and filter lifespan, optimizing adsorbent performance, fixed bed reactor design, and multi-component adsorption processes for more efficient, sustainable gas purification. It is widely used in gas separation & purifaction research such as carbon capture analysis.
Key Feature
Feature Icon
MFC Inlets
4-8 Gas Inlets +2-3 vapor
Feature Icon
Vapor Generation
2-3 inlets P/Pₒ 0.1%-100%, ±1%
Feature Icon
PSA Options
0-1Mpa/ 3Mpa/ 6Mpa/ 10Mpa
Feature Icon
Various Column Options
1ml, 2ml, 8ml, 100ml, kilogram level
Feature Icon
Activation
Purging or Vacuum
Feature Icon
Outlet Quantify
Concentration, Flowrate and Adsorption Amount
Feature Icon
Low flow detection
MS to detect 0.2SCCM
Feature Icon
Compatibility
TCD/ Mass Spectrometer/ Infrared
Feature Icon
Thermostatic Pipeline
Air bath thermostat system to 50 °C ±0.1 °C
Specifications
Specifications Details
Gas Inlets 4-8 MFC Inlets
Mass Flow Controller MFC Options 10 SCCM; 20 SCCM; 50 SCCM; 80 SCCM; 200 SCCM; 500 SCCM; 1000 SCCM; 2000 SCCM
Vapor generation 2-3 vapor generation system, P/Pₒ 0.1%-100%, ±1%
Optional Springe Pump vapor 10ppm<P/P0<20%,±1% ;Gas 1ppm<C<5%,±1%
Pipeline regular gas, vapor, Optional Corrosive gas
Pipeline thermostat PCT airbath ambient ~50℃,accuracy ±0.1℃
Column options 1ml; 2ml; 8ml; 100ml; customized sizes and length
Activation Mehod Purging; Optional vaccum; Optional reverse purging
Heating Heating length 100mm, ambient ~400℃, 30 stage programmed heating
Pressure sensor Standard 0-200kPa, accuracy 0.1%
Temperature sensor High-precision platinum resistance temperature sensor
Thermostatic Waterbath -20℃~80℃, accuracy ±0.1℃
TCD Built-in TCD
High pressure Optional PSA 1Mpa/3Mpa/6Mpa/10Mpa
Mass Spectrometry Low flow rate detection 0.2 SCCM
Real time concentration testing
Spotting frequency less than 1 s ,Smooth Breakthrough Curve
Mass number: default 1-100amu; optional 1-200amu or 1-300amu;
Filament: iridium-plated filament, with backup, software switching;
Detection limit: 1PPM (Kr in air);
Scanning speed: up to 1.8ms/amu, scanning step 0.1amu;
Response speed: ultra-fast response at a micro-flow sampling volume as low as <2SCCM, response time <1 second;
LightCycler® PRO system
Reviews