The Patient Monitors YR02170 // YR02171 // YR02172 deliver advanced patient monitoring with their multi-channel display and big font interface for easy readability. These monitors feature ST and arrhythmia analysis, drug dose calculation, and an OxyCRG dynamic view display, making them essential tools in any healthcare setting. They are equipped with apnea alarms for respiration monitoring, a robust alarm review system, and NIBP overpressure protection. The monitors are versatile, featuring both rechargeable battery options and AC/DC compatibility, and can easily integrate into either wired or wireless networks.

Features
Multi-channel display
Big font interface
ST and arrhythmia analysis
Drug dose calculation and titration table
OxyCRG dynamic view display
Respiration monitoring with apnea alarms
Alarm review, arrhythmia review
NIBP over pressure protection
Plug-in rechargeable battery, AC/DC available
Supporting wire or wireless network

Technical Specifications
Model YR02170 YR02171 YR02172
ECG
Lead mode 5 Leads(RA,LA,LL,RL,V)
Connection method I, II, III,AVR,AVL,AVF,V
Lead Mode 3 Leads (RA,LA,LL)
Connection method I, II,III
Waveform 1ch
Gain x250, x500, x1000, x2000
HR Range Adult: 15~300bpm
Neo/Ped 15~350bpm
Accuracy ±1% or ±1bpm
Resolution 1bpm
Sensitivity >200(uVp-p)
Differential input impedance ≥5MΩ
ST segment Monitoring Range
Measure Range -2.0~+2.0mV
Measure Accuracy -0.8mV~+0.8mV
Heart Rate
Measuring range 0~350bpm 20~300bpm
Accuracy ±1bpm
Resolution 1bpm
Sensitivity >200UVp-p
Respiration
Method Impedance between R-F(RA-LL)
Differential Input Impedance >2.5MΩ
Measuring Impedance Range 0.3~3.0 MΩ
Base line Impedance Range 200~4000Ω
Bandwidth 0.1~2.5Hz
Resp. Rate Adult: 2~120BrPM
Neo/Ped 2~150BrPM 0~150BrPM
Resolution 1 BrPM
Accuracy ±2 BrPM
Alarm 10~40S
NIBP
Method Oscillometric
Mode Manual/Auto/STAT
Measuring Interval in AUTO Mode 1,2,3,4,5,10,15,30,60,90,120,180,240,480(Min)
Measuring Period in STAT Mode 5 Min
Pulse Rate Range 40~240bpm
Alarm Type SYS, DIA, MEAN
Resolution
Pressure 1mmHg
Accuracy Maximum Mean error: 5mmHg
Maximum Standard deviation 8mmHg
SPO2
Display Number of SPO2,waveform of capacity,Pulse
Measuring range 0~100%
Resolution 1%
Accuracy 70~100% (±2%)
Alarm system Audio-video alarm
Pulse rate range 0~300bpm
TEMP
Channel 2
Measuring and Alarm Range 0~50ºC
Resolution 0.1ºC
Accuracy 0.1ºC
Actualization interval about 1 Second.