Description
A high degree of automation, ergonomics and quality of results in one compact bench top analyser
User friendly interface via ergonomic and intuitive software providing all the functions you need
Proven technology delivering the best quality of result
*This product may not be available in your country or region at this time. Please contact your HORIBA Medical sales representative or distributor for more information
Overview
Fixed cycles provide continuous throughput of 90 colourimetric tests/hour
Optional high throughput ISE module (270 tests/hour)
Reagent management with unique “Pentra” cassette
Fully automatic cuvette management – 2 racks of 96 single use cuvettes
Dedicated waste compartment for used cuvettes and contaminated liquid
Integrated computer and cooling unit (Peltier)
Product Description
Analysis Method Types:
Spectrophotometry: Colorimetry and Turbidimetry
Potentiometry: Direct (Serum or Plasma) and Indirect (Urine)
15 parameters per reagent tray
Optional ISE Module (Na+, K+, Cl-)
Maximum Throughput: up to 360 test/h (140 tests/h in standard configuration)
CE Marked
Sample Handling
Sample Capacity: 15 positions in refrigerated compartment
Dedicated stat position in Random access
Positive Sample Identification: Integrated Barcode Reader
Sampling Needle: Level, and Shock Detection
Sample Collection Format: 2, 3, 4, 5, 7 and 10 mL (diameter: from 13 to 6mm)
Sample Specimen: Serum, Plasma, Urine, CSF, Homogeneous Fluids
Sample Volume: 2 to 45 µL (0.1 µl increment)
Automatic Sample Dilution: from 1/2 to 1/30,625
ISE: 20 µL (Indirect) or 93 µL (Direct)
Automatic Post Concentration: from x2.0 to x 20.0
Automatic Re-run
Calibrator/Control Handling
Calibrator/Controls Positioning on Sample Tray in the Refrigerated compartment
Automatic Standard Dilution Series:
Dilution Factors: Main Direct 1/2 – 1/175
Dilution Factors: Main Indirect 1/176 – 1/30 6258
Reagent Handling
15 parameters on board in a closed refrigerated area (8-15°C)
Positive Reagent Identification: Integrated Barcode Reader
Reagent Needle: Level Detection and shock detection
Reagent management with cassettes: Automated Reagent On-board Stability Check plus continuous test countdown check by capacitive effect.
Reagent Volume: from 20 to 350 µL
Reaction System
Reaction Volume: 120 to 450 µL
Reaction Temperature: Air bath at 37°C
Photometer Reaction Cycle:20 seconds
Homogenization with Stirring Paddle
Reaction Time: 1 to 29 cycles
Disposable Acrylic Cuvettes
Automatic Cuvette Changer
Cuvette Capacity: 192 cuvettes (2 racks of 96 cuvettes)
7 Integrated Calculation Algorithms
Reviews
There are no reviews yet.