Description
The APHA-380 is an analyzer for measuring hydrocarbon in ambient air and other background gases, for air quality control as well as for variety of industrial applications. HORIBA’s state-of-the-art flame ionization detector(FID) with selective combustion enables high sensitivity and stable real-time continuous measurement.
Ultimate Performance
Flame ionization detector with selective combustion provides excellent sensitivity, stability and robustness
Simultaneously measures THC, CH4 and NMHC
Real-time continuous measurement
Single detector eliminates zero drift
Wide measurement range with up to 5 ranges selectable, minimum 0-5 ppmC and maximum 0-100 ppmC
Enhanced Lower Detection Limit and response time
User-Friendly Interface & Functionality
Durable 7-inch wide color touch screen LCD with intuitive interface and trend graph
Selectable response time (moving average value), and calculation method
Programmable dilution ratio
Dust filter accessible from the front panel for easy daily maintenance
â– APHA-380 Specifications
Component Methane, non-methane hydrocarbons, total hydrocarbons (CH4, NMHC, THC)
Measuring principle Flame lonization Detector Method (FID) with Selective Combustion
Measurement range 0-5/10/20/50/100 ppmC (up to 5 ranges selectable, auto-range)
Lower Detection Limit (2σ) < 0.02 ppmC*1
Measurement unit ppmC, ppm
Sample gas flow rate Approx. 0.8 L/min
Repeatability ±1.0% of full scale
Linearity ±1.0% of full scale
Zero drift < 0.025 ppmC (24 h)
Span drift < 0.5% of full scale (24 h)
Response time (T95) < 40 s from the inlet*1
Display 7-inch color LCD with touch panel
Communication Ethernet × 2 (Modbus® TCP), RS-232C × 1 (Modbus® RTU) , USB flash drive × 1
Analog output (option) Maximum : 3 channels (insulated)
DC4-20 mA, DC 0-0.1 V, DC 0-1 V, DC 0-5 V or DC 0-10 V
Digital output (option) Relay contact output for range 3 channels, relay contact output for other 6 channels
Digital input (option) Maximum : 4 channels, non-isolated input
Installation environment Operation temperature : 0-40℃ (32℉ – 104℉), relative humidity : 85% or less
Temperature and pressure compensation With
Sampling pump and filter Internal
Power supply AC 100-240 V±10% (max. voltage: AC 250 V) 50/60 Hz, consumption 230 W
Dimensions, weight 430 (W) x 568 (D) x 221 (H) mm, Approx. 26 kg
Compliance CE, UKCA, KC, FCC, China RoHS